TECHNICAL
Technical
Accurate Technical Information in Wyong
Design Criteria Earthsafe Environmental Model ES10PC
Aerated Wastewater System
Non Conventional
Loading
10 persons at the following rates per person day
150 litres per day
70 grams BOD5
70 grams suspended solids
15 grams total nitrogen
2.5 grams total phosphorous
Anaerobic Chamber
3247 litres
Minimum size allowed based on AS1546 is 24 hours retention and 3 years sludge retention + 3050 litres
Divided into tow compartments – primary 1 = 66% capacity, primary 2 = 34% capacity
Aerobic Chamber
2852 litres which is 45.6 hours detention or 285.2 litres per person
Media surface area 200m2/m3 – refer attached specification sheet
Based on 8.42 grams BOD5 removed per m2 surface area
Freeboard
1000 litres at 250mm below top of insert
1600 litres total freeboard prior to over flow into chlorination and pump well chamber
Based on 8.42 grams BOD5 removed per m2 surface area
Air Supply
Model Hiblow HP80 Blower or equivalent – refer attached specifications
Minimum D.O. Level 2.0mg/L
Clarifying Chamber
0.5289m2 surface area
460 litres – 7.36 hours retention
Sludge hopper minimum 55degrees to horizontal
Call us now: 1300 327 847
Email Us Now
Disinfection Chamber
165 litres
Based on maximum flow 5L.P.M at high flows. Contract time will be 33 minutes
Adjustment cap to increase or decrease chlorination
2 chlorine canisters standards with space to add third canister if required
Maintains free chlorine residual of 0.2 to 2mg/L
Minimum 4 months chlorine storage
Irrigation Chamber
165 litres
Dab600 irrigation pump or equivalent minimum – refer attached specification
Concrete Tanks
Must be accredited by Director general of NSW Health
Other
All components stainless steel or other non corroding material
Plastic and perishable components will retain their integrity under normal operating conditions
All components to be firmly fixed to withstand loads encountered during transpiration, installation and normal operation
All mechanical and electrical equipment not designed for submergence will be above maximum water level of system
All equipment suitable for continuous and intermittent operation
Alarm System
Audible and visual alarms with muting facility for the audible alarm
Alarm indication for electrical, blower and pump failure
Mute switch will reset after 24 hours
Alarm will be visible from residence
All wiring in accordance with AS3000 “Electrical Installation – Buildings Structures and Premises”
Noise
Maximum 55 DB (A) at 1 meter
Rivatec Environmental Pty Ltd ES10PC 1546.3 June 2019
Download
Rivatec ES10PC-A4_1_1
Download
Signed CofA Rivatec SEPS014 Jul 2019
Download
Warranty Certificate
Download
Warranty Claim Form
Download
1546.3 2017 May 2020-RWT10-2
Download
CofA Rivatec RWT10
-2 STS-AWTS044 June 2020
Download
Signed CofA Rivatec ES10PC AWTS009 Dec 2020
Download
58389 RWT10-2 Booklet Proof - 2019
Download
Signed CofA Rivatec SEPS014 Dec 2020
Download
Address
PO BOX 605
Wyong, NSW 2259
Contacts
Phone:
1300 327 847
Email Us
Links
Terms and Conditions
Privacy
Privacy Policy
Share by: